Skip to main content
. 2020 Oct 13;9(10):1351. doi: 10.3390/plants9101351

Table 1.

LC-MS/MS based method development and validation for four standards.

Marker Compounds tR a (min) Mass/Charge (m/z) Linearity and Range Sensitivity c
Regression Equation b Correlation Coefficient (r2) Linear Range (μg/g) LOD (ng/g) LOQ (ng/g)
Peimisine 5.78 428.316 y = 0.0396x + 0.0630 0.9923 0.1–40 0.01 0.04
Sipeimine 8.22 430.332 y = 0.5426x + 0.1531 0.9968 0.1–40 0.02 0.06
Peiminine 10.72 430.332 y = 0.0047x + 0.0010 0.9967 0.1–40 0.97 3.23
Peimine 11.88 432.347 y = 0.0067x + 0.0016 0.9977 0.1–40 0.56 1.88

a tR: Retention time. b The regression equations are presented as y = mx+c, and y and x are defined as peak area and concentration of the compound, respectively. c LOD: Limit of detection, S/N = 3; LOQ: limit of quantification, S/N = 10.