TABLE 2.

Summary of scan sequences and parameters.

Voxel size (isometric mm, unless otherwise specified) Number of slices (orientation) FOV (cm) TR/TE/TI (ms) Number of volumes Flip angle (°) Duration (min:sec)
T1-weighted MRI 1.0 156 (axial) 25.6 8.2/3.2/600 N/A 12 3:40
Optimized PRESS (dACC) Variable, not isometric 1 (oblique) 24.0 2000/35/NA N/A 90 5:04
Optimized PRESS (rACC) Variable 1 (axial) 24.0 2000/25/NA N/A 90 5:04
Resting-state BOLD EPI 2.9 42 (oblique) 23.2 2000/30/NA 240 77 8:00
Resting-state fieldmap 2.9 42 (oblique) 22.4 700/4.5/NA N/A 54 0:27
Diffusion-weighted MRI 2.0 64 (axial) 24.0 8500/94.2/NA 66 (60 b = 2000, 6 b = 0) 90 9:30
Diffusion-weighted MRI fieldmap 2.0 64 (axial) 24.0 700/4.5/NA N/A 54 0:27
Quantitative T1 2.0 25 (axial) 24.0 3000/25/50 31 77 2:03 per scan (second scan with reverse phase-encoding)