Skip to main content
. 2020 Nov 2;760:143329. doi: 10.1016/j.scitotenv.2020.143329

Table 3.

Molecular detection of SARS-CoV-2 RNA in wastewater samples. Collected samples were tested at t0 and at t1 = 24 h, with subsamples being kept at room temperature and at 4 °C. Two RT-qPCR assays were performed on all extracts, targeting genes N and Orf1b, with an estimated limit of detection (LOD) of 2.5 gc/L (Chu et al., 2020). Average recovery for enveloped viruses from wastewater with the adopted ultrafiltration protocol is estimated at 22% (Ye et al., 2016).

Sampling date: 23/04/2020
Plant t0
t1 (r.t.)
t1 (4 °C)
ID N Orf1b N Orf1b N Orf1b
WWTP_A A-U-1 + +
A-U-2
A-U-4 +
WWTP_B B-U-1



Sampling date: 05/05/2020
Plant t0
t1 (r.t.)
t1 (4 °C)
ID N Orf1b N Orf1b N Orf1b
WWTP_A A-U-1 + +
A-U-2 +
A-U-3
A-U-4 +
B-T-1 + +
WWTP_B B-U-1
B-T-1 +