Skip to main content
. Author manuscript; available in PMC: 2021 Dec 1.
Published in final edited form as: Biomech Model Mechanobiol. 2020 Apr 28;19(6):2683–2692. doi: 10.1007/s10237-020-01331-6

Table 3:

End-systolic strain components averaged at the mid-LV in the mid-myocardial layer. Data are mean ± standard deviation; n = 5. Multiple comparisons between groups (i.e., experimental CMR, three-state model, two-state model) were performed using one-way ANOVA with post-hoc Bonferroni t-tests..

Ecc Err Ell Ecr Ecl Erl
CMR −0.200±0.022 0.553±0.075 −0.159±0.010 0.068±0.013 0.055±0.012 0.085±0.017
3 state −0.189±0.011 0.522±0.061 −0.106±0.011* 0.056±0.010 0.062±0.014 0.087±0.012
2 state −0.185±0.010 0.510±0.056 −0.085±0.008* 0.058±0.014 0.064±0.011 0.091±0.013
*

p < 0.05 for comparisons between model-predicted and experimentally measured strains.

p < 0.05 for comparisons between three-state model and two-state model