Skip to main content
. 2021 Jan;119:107500. doi: 10.1016/j.foodcont.2020.107500

Table 6.

Post-food safety training microbial counts on equipment surfaces in OFSP purée processing plant (LOG CFU/cm2)a

Sample TVC Yeast & Molds S. aureus Enterobacteriaceae. Coliforms E. coli
Knives 3.8 ± 0.1 fg 2.1 ± 0.8bc 2.7 ± 0.0b 2.8 ± 0.0cdef 2.7 ± 0.2de nd*
Tables 3.7 ± 0.2 fg 2.2 ± 0.2bc 1.5 ± 0.3 ab 2.9 ± 0.40def 2.5 ± 0.3cde nd*
Cooling trays 2.5 ± 0.3de 2.3 ± 0.1bc nd* 1.9 ± 0.1bcd 1.8 ± 0.1bcd nd*
Purée machine 3.0 ± 0.5e 2.1 ± 0.0bc nd* 2.0 ± 0.1bcd 1.6 ± 0.3bcd nd*
Weighing spoons 3.6 ± 0.0f nd* nd* 2.4 ± 0.1defg 2.9 ± 0.0de nd*
Packaging bags 1.1 ± 0.1b nd* nd* nd* nd* nd*
Freezers 4.9 ± 0.1i 3.7 ± 0.1e 1.3 ± 0.2 ab 3.8 ± 0.4 fg 3.6 ± 0.3a nd*
Cold boxes 1.6 ± 0.4bc 1.6 ± 0.1bc 0.6 ± 0.1 ab 0.9 ± 0.0 ab 0.9 ± 0.0 ab nd*
Truck 3.8 ± 0.0 fg 3.1 ± 0.0cde nd* 1.8 ± 0.1bcd 1.1 ± 0.2abc nd*

*nd-not detected.

a

All values represent mean microbial counts and standard deviations. Values with different superscript letters in each column are significantly different (p < 0.05)