Table II.

Fit factor after one and two decontamination cycles

Respirator Fit factor
Baseline
After one cycle
After two cycles
Median (Q1–Q3) Median (Q1–Q3) One cycle vs baseline
P-value
Median (Q1–Q3) Two cycles vs baseline
P-value
Bimedica Naturcare® FFP2 Conical with valve (128944) 1.37 (1.33–1.38) 13.64 (12.34–13.64) 0.002a 2.41 (2.32–2.72) 0.002a
Dräger X-plore® 1730 V FFP3 161.79 (146.58–176.87) 107.52 (102.64–147.05) 0.063 553.68 (511.16–558.63) 0.002a
Dräger X-Plore® 1920V FFP2 200.00 (200.00–200.00) 200.00 (200.00–200.00) 0.317 200.00 (200.00–200.00) 0.317
Dräger X-plore® 1930V FFP3 102.94 (97.59–110.85) 141.67 (136.22–148.11) 0.003a 221.85 (221.85–251.26) 0.002a
Dromex® 3231 FFP3 NR D 34.97 (31.04–42.99) 33.89 (29.86–39.28) 0.406 71.39 (63.99–80.68) 0.003a
Garry Galaxy N95 Respirator Mask 4.70 (4.45–4.98) 4.46 (4.34–4.62) 0.253 6.36 (6.01–6.48) 0.007a
HY 9330 FFP3 NR 902.44 (846.04–1747.87) 892.92 (892.92–1190.56) 0.847 885.60 (844.12–942.55) 0.565
Oxyline X310SV FFP3 NR D 214.00 (202.11–269.77) 55.02 (54.37–64.51) 0.002b 88.06 (82.91–95.29) 0.002b
Pioneer® Safety EP005 FFP2 17.42 (16.67–20.12) 17.58 (15.83–20.14) 0.848 14.80 (13.88–18.63) 0.140
PURVIGOR KN95 3D 7.32 (7.15–7.80) 6.69 (6.42–7.45) 0.110 9.60 (9.20–10.42) 0.003a
VENUS V-420-V 23.19 (22.22–25.40) 21.32 (20.92–22.37) 0.110 10.08 (9.81–10.98) 0.002b
3MTM AuraTM 9320+ FFP2 NR D 474.00 (454.25–546.92) 333.80 (278.17–388.35) 0.003b 307.63 (277.29–358.13) 0.013b
3MTM VFlexTM 1802S 104.30 (99.04–116.13) 100.44 (76.53–113.44) 0.565 82.54 (61.65–94.89) 0.009b
3MTM 8822 FFP2 NR D 200.00 (200.00–200.00) 115.33 (102.12–133.87) 0.001b 85.00 (80.28–86.85) 0.001b

Q1, Quartile 1; Q3, Quartile 3.

aIncrease in fit factor with a P-value <0.05.

bDecrease in fit factor with a P-value <0.05.

For calculating median, Q1, Q3 and P-values, seven consecutive fit factor measurements were taken for 1 min at regular 10-s intervals in each phase of the research (baseline, after one decontamination cycle and after two decontamination cycles).

Three units of each respirator model were used, one for each phase of the research.