Table II.

Quantitative Comparison of Different Channel Attention Methods for Skin Lesion Segmentation. Enc, Dec and Enc&Dec Means Channel Attention Blocks Are Plugged in the Encoder, the Decoderand Both Encoder and Decoder, Respectively

Network Pmax Para Dice(%) ASSD(pix)
Baseline - 1.9M 87.77±3.51 1.23±1.07
C-A(Enc) × 2.7M 91.06±3.17 0.73±0.56
C-A(Enc) 2.7M 91.36±3.09 0.74±0.55
C-A(Dec) × 2.7M 91.56±3.17 0.64±0.45
C-A(Dec) 2.7M 91.68±2.97 0.65±0.54
C-A(Enc&Dec) × 3.4M 90.85±3.42 0.92±1.40
C-A(Enc&Dec) 3.4M 91.63±3.50 0.58±0.41