Table 3. Overview of Advantages and Disadvantages for Optical Measurement Principles Based on Species-Independent Parameters to Identify a Suitable Techniquea.
Absorbance | Scattered light | Autofluorescence | |
---|---|---|---|
High cell numbers | – | + | + |
Different cell size | – | + | – |
Different cell walls | – | + | + |
Pigments | + | – | + |
Fluorescent metabolites | – | – | + |
+ indicates a preferred principle.