Table 3. Overview of Advantages and Disadvantages for Optical Measurement Principles Based on Species-Independent Parameters to Identify a Suitable Techniquea.

Absorbance Scattered light Autofluorescence
High cell numbers + +
Different cell size +
Different cell walls + +
Pigments + +
Fluorescent metabolites +
a