Table 5. Imaging parameters for the LGE scar assessment utilized in several leading centers worldwide.
Source | Center | Scanner | TR/TE (ms) | Acq. T (min) | Gadolinium dose | Spacing (mm3) |
---|---|---|---|---|---|---|
Badger et al. (2010) | Utah, USA | 1.5 T, SA | 5.5/2.3 | 15 | 0.1 mmol/kg | 1.25 × 1.25 × 2.5 |
Taclas et al. (2010) | Boston, USA | 1.5 T, PA | 3.8/1.52 | 15~25 | 0.2 mmol/kg | 1.3 × 1.3 × 4.0/5.0 |
Hunter et al. (2013) | Imperial/Barts, UK | 1.5 T, PA | N/A | 20 | 0.4 mmol/kg | 1.5 × 1.5 × 4.0 |
Bisbal et al. (2014) | Barcelona, Spain | 3T | 2.3/1.4 | 25~30 | 0.2 mmol/kg | 1.25 × 1.25 × 2.5 |
McGann et al. (2014) | CARMA† | 1.5 T; 3 T, SA | 5.2/2.4; 3.1/1.4 | 5~9; 6~12 | 0.1 mmol/kg | 1.25 × 1.25 × 2.5 |
Fukumoto et al. (2015) | John Hopkins, USA | 1.5 T, SA | 3.8/1.52 | 10~32 | 0.2 mmol/kg | 1.3 × 1.3 × 2.0 |
Harrison et al. (2015a) | KCL, UK | 1.5 T, PA | 6.2/3.0 | 20 | 0.2 mmol/kg | 1.3 × 1.3 × 4.0 |
Akoum et al. (2015) | DECAAF† | 1.5 T; 3 T | 5.2/2.4; 3.1/1.4 | 15 | 0.1~0.2 mmol/kg | 1.25 × 1.25 × 2.5 |
Cochet et al. (2015) | Bordeaux, France | 1.5 T, SA | 6.1/2.4 | 15~30 | 0.2 mmol/kg | 1.25 × 1.25 × 2.5 |
SA: Siemens Avanto; PA: Philips Achieva; TR: repetition time; TE: echo time; Acq. T: acquired time after contrast agent injection; CARMA: Comprehensive Arrhythmia Research and Management; DECAAF: Delayed-Enhancement MRI Determinant of Successful Radiofrequency Catheter Ablation of Atrial Fibrillation.
Here, † refers to multiple centers.