Table 4.
Review of studies assessing the accuracy of 1-D model pulse waveforms
| References | Test Data | Simulated Arteries | εP | εQ | εU | εA | |
|---|---|---|---|---|---|---|---|
| Mynard et al. | (32) | 3-D data | Carotid bifurcation | - | - | * | - |
| Reymond et al. | (87) | 3-D data | Upper Ao and supra Ao arteries | * | * | - | - |
| Grinberg et al. | (88) | 3-D data | 50 larger intracraneal arteries | * | * | - | - |
| Xiao et al. | (89) | 3-D data | CCA, thoracic Ao, aortic bif. | 1.4 | 2.1 | - | 2.6 |
| Xiao et al. | (89) | 3-D data | 20 larger sys. arteries | 2.1 | 4.9 | - | - |
| Boileau et al. | (90) | 3-D data | CCA, thoracic Ao, aortic bif. | 1.2 | 2.6 | - | 4.3 |
| Alastruey et al. | (91) | 3-D data | Upper Ao and supra Ao arteries | 2.0 | 5.0 | - | 3.0 |
| Jin and Alastruey | (92) | 3-D data | Abdominal Ao, carotid and iliac§ | 5.4 | 7.3 | - | - |
| Bessems et al. | (18) | in vitro | Ao† | * | * | - | - |
| Alastruey et al. | (93) | in vitro | 37 larger sys. arteries | 2.5 | 10.8 | - | - |
| Saito et al. | (94) | in vitro | 9 larger sys. arteries | 10.0 | * | - | - |
| Huberts et al. | (95) | in vitro | Upper-limb arteries | * | * | - | - |
| Boileau et al. | (90) | in vitro | 37 larger sys. arteries | 4.0 | 25.6 | - | - |
| Jin and Alastruey | (92) | in vitro | Ao | 5.0 | - | - | - |
| Avolio | (46) | human | 128 larger sys. arteries | - | - | * | - |
| Stettler et al. | (47, 48) | human | Ao and lower limb arteries | * | * | - | - |
| Olufsen et al. | (96) | human | 29 larger sys. arteries | - | * | - | - |
| Reymond et al. | (21) | human | 103 larger sys. arteries | * | * | - | - |
| Reymond et al. | (64) | human | 94 larger sys. arteries | 6.0‡ | 11.0 | - | - |
| Willemet et al. | (97) | human | Lower-limb arteries | 9.6 | - | 16.0 | - |
| Guala et al. | (65) | human | Larger sys. arteries | 13.0 | - | - | - |
| Mynard and Smolich | (32) | human | Larger sys. and pul. arteries | * | * | * | - |
| Alastruey et al. | (91) | human | Upper Ao and supra Ao arteries | 10.0 | 7.0 | - | 8.0 |
| Strocchi et al. | (84) | human | 55 larger sys. arteries | * | * | - | - |
| Charlton et al. | (28) | human | 116 larger sys. arteries | * | * | - | - |
| Steele et al. | (98) | animal | Aortic bypass | - | 4.2 | - | - |
| Mynard et al. | (99) | animal | Left conduit coronary arteries | - | 16.7 | - | - |
The third column shows the type of reference data used in each study. Upper bounds for relative errors (in percentage) for pressure (εP), flow rate (εQ), flow velocity (εU) and cross-sectional area (εA) wave morphology, calculated as described in the corresponding article, are shown when available. (Adapted from Ref. 92). Ao, aorta; bif., bifurcation; CCA, common carotid artery; pul., pulmonary; sys., systemic. -, no comparison made.
*Qualitative comparison; †according to the dimensions shown in Fig. 4 of (18); ‡except at the abdominal aorta, where root mean square error is 21%; §for stenosis and aneurysm sizes of up to 85% and 400%, respectively.