Skip to main content
. Author manuscript; available in PMC: 2023 Oct 12.
Published in final edited form as: Environ Res Lett. 2017 Sep 15;12:095009. doi: 10.1088/1748-9326/aa804f

Table 3.

Emission factors on a per-fuel, per-task, and per-energy-delivered basis for PM2.5 and CO from traditional chimney stoves burning wood (n=15) and the THU semi-gasifier stoves burning pelletized biomass (n=16), 6 months post-stove installation.

Pollutant Traditional Stove
Mean ± St Dev(ISO Tier)
THU Stove
Mean ± St Dev(ISO Tier)
PM2.5 (g/kg-fuel) 2.3 ± 1.6 0.9 ± 0.9
PM2.5 (g/task) 3.7 ± 3.3 0.5 ± 0.4
PM2.5 (g/MJda) 0.612 ± 0.457 (1) 0.123 ± 0.125 (3)
CO (g/kg-fuel) 53 ± 17 49 ± 25
CO (g/task) 88 ± 49 31 ± 21
CO (g/MJd) 14 ± 5 (1) 7 ± 4 (4)

CO, carbon monoxide; ISO, International Standards Organization; PM, particulate matter

a

megajoule delivered on a dry basis