Table 1. Building fabric characteristics of the base case model.

Element Construction detail (external to internal) U-value
(W/m2K)
Solar absorptivity Solar emissivity
Main house
External walls 105 mm brick + 50 mm cavity filled with UF foam insulation + 100 mm dense concrete block + 12.5 mm plasterboard 0.60 0.8 0.9
Party wall 12.5 mm plaster + 215 mm brick +
12.5 mm plaster
1.43
Internal walls 12.5 mm plaster + 105 mm brick +
12.5 mm plaster
1.91
Ground floor 125 mm concrete slab + timber battens +
20 mm timber flooring
1.74
Internal floor/ceiling
(uninsulated)
20 mm softwood flooring + 150 mm timber joists + 12.5 mm plasterboard 1.55
Windows 6/12/6 double-glazing (argon filled) + PVC frame 1.57 0.85
Doors
Converted loft
40 mm plywood 2.06 0.7 0.85
Loft roof (insulated) Concrete tiles + 50 mm ventilated air space + 150 mm PU insulating board between and under rafters + 12.5 mm laminated plasterboard 0.16 0.7 0.9
Roof (outside thermal envelope) Concrete tiles + timber battens + timber rafters 5.71 0.7 0.9
Loft walls (insulated) Timber frame + 150 mm phenolic insulating board + 12.5 mm plasterboard 0.25
Internal floor/ceiling
(insulated)
20 mm softwood flooring + 150 mm PU insulation + 12.5 mm plasterboard 0.16
Roof windows 6/12/6 double-glazing (CO2 filled) + PVC frame (0.55g-value) 1.39 0.85