Skip to main content
. Author manuscript; available in PMC: 2024 Dec 9.
Published in final edited form as: Eur J Obstet Gynecol Reprod Biol. 2021 Jun 30;264:1–7. doi: 10.1016/j.ejogrb.2021.06.026

Table 1.

Intraclass Correlation Coefficients for Intra and Inter-reliability for thymic parameters measured on ultrasound scan. 3VV (3 vessel-view), 3VT (3 vessel-trachea view), APD (anterior-posterior diameter), ITD (intrathoracic diameter), TTR (thymic: thoracic ratio), TD (transverse diameter), 3VE (3-vessel-edge). Acceptable ICC values (>0.75 [29]) that are clinically significant (P< = 0.05) are in bold.

Thymus Measurement Intra-observer reliability (n = 5) Inter-observer reliability (n = 5)
ICC (95% CI) P value ICC (95% CI) P value
3VV APD 0.984 (0.851-0.998) 0.001 0.913 (0.35-0.99) 0.012
ITD 0.981 (0.860-0.998) 0.001 0.931 (0.37-0.99) 0.015
TTR 0.903(0.232-0.990) 0.024 0.771(−0.256-0.968) 0.052
TD 0.954 (0.516-0.995) 0.008 0.872 (0.700-0.986) 0.035
Perimeter 0.962 (0.648-0.996) 0.002 0.788 (0.264-0.976) 0.041
3VT APD 0.894(0.256-0.989) 0.022 0.731(−0.358-0.782) 0.052
ITD 0.989 (0.917-0.999) <0.001 0.210(−0.072-0.782) 0.077
TTR 0.996(0.966-1.000) <0.001 0.705(0.099-0.963) 0.015
TD 0.852(−0.200-0.984) 0.049 0.790(−0.590-0.828) 0.375
3VE 0.988 (0.881-0.999) 0.001 0.901 (−0.191-0.990) 0.032