Skip to main content
. 2020 Oct 26;21(6):527–544. doi: 10.1007/s10162-020-00772-1

Table 3.

Fixed parameter estimates of the LMM with absolute SRTs as dependent variable

Parameter LMM factor type Estimate SD t P
Intercept − 21 7.4 2.8 0.021
CI + HA Fixed factor − 1.3 0.48 2.8 0.0081
N Fixed factor + 6.5 0.50 13 < 10−6
HAprior Fixed factor + 0.73 1.6 0.45 0.67
SRTHA Fixed co-variate + 0.16 0.094 1.7 0.10
PTA125–500 Fixed co-variate + 0.13 0.079 1.6 0.14
Age Fixed co-variate + 0.10 0.070 1.5 0.17

CI + HA: bimodal hearing (parameter estimate is 0 for CI only); N: babble noise (0 for steady-state noise); SRTHA: SRT with only HA; PTA125–500: average pure-tune audiometric threshold across 125, 250, and 500 Hz; LMM: linear mixed model