Skip to main content
. 2020 Nov 2;9(12):6. doi: 10.1167/tvst.9.12.6

Table 2.

Clinical Eye Examination Parameters Determined via Pachymetry, STT, and Applanation Tonometry

Pachymetry CCT (µm) STT Tear Flow (mm) Applanation Tonometry IOP (mm Hg)
Groups Treatment to the Eye Study Time Day-3 Study Time Day-7 Study Time Day-3 Study Time Day-7 Study Time Day-3 Study Time Day-7
I (Naive) No treatment 363.0 ± 5.1 367.4 ± 4.2 10.0 ± 0.7 10.2 ± 0.6 10.7 ± 0.7 9.0 ± 0.8
II (TED) TED (without SM exposure) 365.0 ± 5.0ns (naive vs. TED) 372.6 ± 7.7 ns (naive vs. TED) 9.5 ± 0.8ns (naive vs. TED) 8.4 ± 0.5ns (naive vs. TED) 8.2 ± 0.9ns (naive vs. TED) 8.6 ± 0.7ns (naive vs. TED)
III (SM) SM vapor 515.0 ± 5.6**** (naive vs. SM) 540.2 ± 14.0**** (naive vs. SM) 27.5 ± 0.5**** (naive vs. SM) 25.8 ± 1.3**** (naive vs. SM) 9.7 ± 1.0ns (naive vs. SM) 8.4 ± 1.1ns (naive vs. SM)
IV (SM+TED) SM vapor + TED 420.0 ± 5.2**** (SM vs. SM+TED) 412.2 ± 4.3**** (SM vs. SM+TED) 16.5 ± 2.3*** (SM vs. SM+TED) 16.0 ± 0.9*** (SM vs. SM+TED) 10.0 ± 0.7ns (SM vs. SM+TED) 9.0 ± 1.0ns (SM vs. SM+TED)
Age-matched Nave control Both eyes left untreated 360.0 ± 5.2 366.4 ± 4.1 11.0 ± 0.4 10.3 ± 0.4 9.7 ± 0.6 9.2 ± 0.5
****

P < 0.0001.

***

P = 0.0001.

ns, not significant; data represented in mean ± SEM.