Skip to main content
. 2020 Oct 31;9(11):768–777. doi: 10.1302/2046-3758.911.BJR-2020-0019.R2

Table I.

Contact area, contact pressure, von Mises stress, and equivalent plastic strain of ultra high molecular weight polyethylene, highly cross-linked polyethylene, and vitamin E-stabilized polyethylene posts in fixed-bearing and mobile-bearing knee prostheses under neutral and malrotation contact.

P. type Contact area, mm2 Contact pressure, MPa von Mises stress, MPa Plastic equivalent strain, %
Fixed-bearing Mobile-bearing Fixed-bearing Mobile-bearing Fixed-bearing Mobile-bearing Fixed-bearing Mobile-bearing
Neutral Malrotation Neutral Malrotation Neutral Malrotation Neutral Malrotation Neutral Malrotation Neutral Malrotation Neutral Malrotation Neutral Malrotation
UHMWPE 26.3 14.3 26.3 27.9 25.2 51.3 25.7 29.4 19.3 30.9 19.7 21.2 2.3 15.0 2.3 3.1
HXLPE 28.0 14.4 28.0 30.3 23.8 46.2 24.1 27.3 17.8 29.1 18.1 18.7 3.0 15.8 2.8 3.6
VEPE 26.3 14.3 26.3 27.1 26.4 54.7 26.9 31.0 21.1 32.0 21.3 23.2 1.7 14.9 1.8 2.8

HXLPE, highly cross-linked polyethylene; P., polyethylene; UHMWP, ultra high molecular weight polyethylene; VEPE, vitamin E-stabilized polyethylene.