Skip to main content
. 2020 Nov 9;29(11):3641–3647. doi: 10.1007/s00167-020-06344-3

Table 2.

Particle load with and without LAF depending on time of measurement

n 0.3 µm 0.5 µm 1 µm 2 µm 5 µm 10 µm
LAF
 Empty OR 18 20,632 ± 49,303 2876 ± 6270 452 ± 825 236 ± 473 88 ± 184 59 ± 182
 Setting prepared 18 11,406 ± 16,111 3573 ± 3822 1737 ± 2194 1198 ± 1761 560 ± 955 265 ± 786
 Ongoing operation 18 19,401,148 ± 55 803,469 1,704,937 ± 4,476,903 168,806 ± 386,736 36,474 ± 76,345 2267 ± 4059 668 ± 1 143
 Factor 940 592 373 154 25.7 11.3
 p (Friedman) p < 0.01 p < 0.01 p < 0.01 p < 0.01 p = 0.174 p = 0.057
Non -LAF
 Empty OR 18 17,853,868 ± 12,096,453 1,553,190 ± 1,021,798 64,291 ± 30,292 7636 ± 2707 825 ± 581 353 ± 321
 Setting prepared 18 26,792,344 ± 11,271,949 2,778,190 ± 1,515,588 167,070 ± 83,685 39,988 ± 11,521 8157 ± 2467 3455 ± 1475
 Ongoing operation 18 56,953,435 ± 68,735,379 4,777,277 ± 3,568,511 366,304 ± 330,977 95,495 ± 91,967 14,674 ± 13,143 5987 ± 5940
 Factor 3.2 3.1 5.7 12.5 17.8 16.9
 p (Friedman) p < 0.01 p < 0.01 p < 0.01 p < 0.01 p < 0.01 p < 0.01