Skip to main content
. 2020 Nov 9;29(11):3641–3647. doi: 10.1007/s00167-020-06344-3

Table 3.

Particle load with and without LAF application depending on the measurement place

n 0.3 µm 0.5 µm 1 µm 2 µm 5 µm 10 µm
LAF
 Operation column (central LAF area) 18 8068 ± 10,197 3298 ± 4464 1845 ± 2991 1207 ± 2229 452 ± 937 196 ± 457
 Anaesthesia device (marginal LAF area) 18 3,991,490 ± 16,915,423 264,144 ± 1,111,856 42,138 ± 174,027 12,466 ± 49,523 1217 ± 3747 442 ± 1303
 Surgical image amplifier (outside LAF area) 18 15,433 628 ± 54,381,711 1,443, 944 ± 4,427,504 127,012 ± 361,229 24,234 ± 63,219 1247 ± 2202 354 ± 469
 Factor 1913 438 69 20 2.8 1.8
 p (Friedman) p < 0.01 p < 0.01 p < 0.01 p < 0.01 p = 0.174 p = 0.57
Non- LAF
 Operation column (central LAF area) 18 28,558,716 ± 18,156,222 2,853,808 ± 1,844,888 185,061 ± 128,992 47,753 ± 46,313 9089 ± 9160 3828 ± 3893
 Anaesthesia device (marginal LAF area) 18 25,956,930 ± 14,670,502 2,735,748 ± 1,774,967 170,770 ± 116,376 43,914 ± 48,841 8147 ± 11,342 3534 ± 5596
 Surgical image amplifier (outside LAF area) 18 47 084 000 ± 71 139 621 3 519 101 ± 3 840 879 241 834 ± 366 363 51,453 ± 90,657 6419 ± 8026 2434 ± 2612
 Factor 1.6 1.2 1.3 1.1 0.7 0.6
 p (Friedman) p < 0.01 p < 0.01 p < 0.01 p < 0.01 p < 0.01 p < 0.01

LAF laminar air flow