Skip to main content
. 2020 May 6;33(4):958–970. doi: 10.1007/s10278-020-00343-z

Table 4.

Comparison of segmentation performance for the PH2 dataset

Methods Sensitivity % Specificity % Accuracy % Dice % Jaccard %
U-Net 81.63 97.76 92.55 87.61 77.95
SegNet 86.53 96.61 93.36 89.36 80.77
FCN 90.30 94.02 92.82 89.03 80.22
Unver and Ayan [8] 83.63 94.02 92.99 88.13 79.54
FrCN [1] 93.72 95.65 95.08 91.77 84.79
iFCN 96.88 95.31 96.92 93.02 87.1