Table 1 –

Model parameter prior sets and bounds

Prior sets fS DI;S DI;Z DΔ;Z T2;S T2;Z ODb

A 0.45 0.6 1.3 0.57 80 60 0.20
B 0.15 0.3 0.9 0.40 75 55 0.45
C 0.40 0.6 1.7 0.40 80 150 0.35
Bounds fS DI;S DI;Z DΔ;Z T2;S T2;Z

Minimum 0 0.07a 0.2a –0.46a 30 30
Maximum 1 1.33a 4.0a 0.86a 300 1000

Diffusivities are in μm2/ms and T2 values are in ms.

a

From enforcing D||;S, D||;Z and D⊥;Z ∈ [0.2 4.0] μm2/ms.

b

The parameters describing spherical harmonic coefficients, p20, Re(p21), Im(p21), Re(p22), Im(p21), are, for simplicity, represented by the corresponding OD from the Watson distribution (Eq. 21) assuming a main direction of [0 0 1].