Skip to main content
. 2020 Oct 19;85:e586–e594. doi: 10.5114/pjr.2020.99833

Table 4.

Area under curve results of receiver operating characteristics demonstrated for those parameters that showed a statistically significant area greater than 0.5

Bin size Variable AUC Sig. Sens. Spec. Criterion Lower bound Upper bound
4 High-intensity long-run emphasis 0.739 0.008 66.7 76.9 > 74.23 0.587 0.891
8 Max spectrum 0.682 0.042 44.4 88.5 > 0.126 0.522 0.842
32 Code similarity 0.714 0.017 55.6 84.6 ≤ 0.005 0.553 0.874
64 Long-run emphasis 0.709 0.019 61.1 76.9 > 39.36 0.554 0.865
Busyness 0.705 0.022 77.8 65.4 > 2.262 0.535 0.875
Large-zone emphasis 0.701 0.025 61.1 76.9 > 99688.3 0.541 0.861
High-intensity large-zone emphasis 0.718 0.015 55.6 84.6 > 140111.2 0.563 0.873
Code similarity 0.707 0.021 50 88.5 ≤ 0.008 0.548 0.867

AUC – area under curve