WashU (any
site) (Malinowski et al
2007) |
No/no |
• Target accuracy
(mean ± SD) < 1 mm |
• 3D axis and independent
1D vertical axis |
• Motorized platform to
carry phantom or dosimetry equipment |
|
LuCa (lung)
(Perrin et al
2017) |
Yes (interior and
exterior)/yes (high level of detail) |
• Stable end in/exhale
(<1 mm) |
• Inflatable/deformable
lungs, skeleton, muscles skin, solid heart, solid mobile tumour
(can hold dosimetric films) |
• Tumour
position varied from day to day for a given intermediary
in/exhale pressure |
• Motion actuated by an air
pump inflating the lungs |
• MR-compatible with
visible deforming lung features |
|
Lung (Cheung
and Sawant 2015) |
Yes (interior and
exterior)/yes (low level of internal detail) |
• <2 mm day-to-day
(ascribed to set-up) |
• Deformable external
shell |
• Latex foam insert for
lungs |
• < 0.25 mm RMS
intra-day |
• Rigid foam diaphragm
actuated by the WashU motion stage |
|
Lung (Biederer
et al
2006, Remmert
et al
2007) |
Yes (interior)/yes (animal
heart and lungs, nodules, airways, no ribs) |
• Maximal diaphragm
displacement precision (SD) 1.90 mm (on CT), 1.47 mm (on
MR) |
• Porcine lung and heart
explants with tracheal tube in saline solution, artificial
pulmonary nodules |
• Water-filled silicon
diaphragm inflated or deflated by a water pump outside the MR
room |
• Reproducibility of
intermediary phases not quantified |
• MR-compatible |
|
Lung (Serban et
al
2008) |
Yes (interior)/yes (only
one lung with vasculature/airways features) |
• Within image resolution
(0.7 × 0.7 × 1.25 mm3) |
• Lung (natural latex
balloon filled with damp sponges) in water, thoracic cavity
(Lucite), diaphragm (motor-actuated piston), tumour (Dermasol
ellipsoid), vascular and bronchial bifurcation (nylon wires and
Lucite beads) |
|
Lung (Steidl
et al
2012) |
Yes (exterior)/yes (low
level of internal detail, cubic tumour) |
Target accuracy
(mean ± SD) = 0 ± 0.09 mm (input versus log files) |
• Artificial skeleton,
rubber skin |
• Tumour: PMMA cube with 20
slots for pinpoint ion chambers and 5 films |
• Sternum-induced thoracic
motion |
• 6D robot-actuated tumour
motion independent of thoracic motion |
|
MAESTRO (lung)
(Haas et al
2014) |
Yes (ribcage only)/yes (no
vasculature) |
• Millimetre positioning
precision |
• Mechanically actuated
ribs, stationary lungs, trachea and spine in hermetic skin (to
be filled with water) |
• Inter-cycle
reproducibility <0.16 mm RMS |
• Robot-actuated tumour
motion |
|
ELPHA (liver)
(Ehrbar et al
2019) |
Yes (interior)/yes (liver
with vasculature) |
•
Reproducibility <0.32 mm RMS (inter- and intra-day) |
• Soft silicon liver with
vasculature (can hold dosimetric devices) |
• Static inferior plate and
motor-driven superior plate |
• Ultrasound and CT
contrast |