Skip to main content
. 2018 Nov;39(11):1995–2000. doi: 10.3174/ajnr.A5815

Table 3:

Comparison of leukocortical lesion counts and volumes on conventional and synthetic PSIRa

Conventional PSIR Synthetic PSIR P Value Conventional vs Synthetic PSIRb Consensus Rating P Value Conventional/Synthetic PSIR vs Consensus Ratingb
Leukocortical lesion count, Rater 1 (No.) 7 ± 17 5 ± 26 .47 5 ± 30 .14/.06
Leukocortical lesion count, Rater 2 (No.) 7 ± 34 7 ± 29 .08 5 ± 30 .008/.96
Leukocortical lesion volume (mL) 0.53 ± 2.46 0.32 ± 2.89 .17
a

All values are given as median ± interquartile range.

b

P value by the Wilcoxon signed rank test.