Skip to main content
. 2018 Dec;39(12):2313–2319. doi: 10.3174/ajnr.A5848

Table 1:

MR signal intensities of hemorrhagic transformation and contrast staining in B0 and GRE imagea

Hemorrhagic Transformation (n = 8) Contrast Staining (n = 9) Total (n = 17) P
B0 <.001
    Score 1 8 (100.00%) 0 (0.00%) 8 (47.06%)
    Score 2 0 (0.00%) 0 (0.00%) 0 (0.00%)
    Score 3 0 (0.00%) 3 (33.33%) 3 (17.65%)
    Score 4 0 (0.00%) 6 (66.67%) 6 (35.29%)
GRE <.001
    Score 1 8 (100.00%) 0 (0.00%) 8 (47.06%)
    Score 2 0 (0.00%) 0 (0.00%) 0 (0.00%)
    Score 3 0 (0.00%) 6 (66.67%) 6 (35.29%)
    Score 4 0 (0.00%) 3 (33.33%) 3 (17.65%)
a

Values are numbers of patients with percentages in parentheses. Score 1, signal intensity was similar to that of the vessel; score 2, signal intensity was lower than that of the gray matter; score 3, signal intensity was similar to that of the gray matter; score 4, signal intensity was higher than that of the gray matter.