Skip to main content
. Author manuscript; available in PMC: 2021 Sep 1.
Published in final edited form as: Otol Neurotol. 2020 Sep;41(8):e1052–e1059. doi: 10.1097/MAO.0000000000002703

Table 3.

Ocular VEMP Means (SD) and Statistical Results of Test Session Comparison

n10 (ms) p16 (ms) Peak-to-peak Amplitude (μv)

Session 1 2 p 1 2 p 1 2 p

ACS 9.74 9.78 .62 15.14 14.96 .18 15.04 15.41 .36
EO (0.64) (0.61) (1.23) (1.22) (12.19) (12.50)

ACS 10.48 10.62 .56 16.77 16.87 .70 9.43 9.58 .77
EC (1.20) (1.21) (1.44) (1.67) (5.68) (5.01)

IH 11.36 11.27 .57 16.47 17.28 .36 35.23 39.25 .27
EO (0.92) (0.70) (1.18) (6.49) (27.59) (22.87)

IH 11.95 11.94 .97 18.08 17.82 .39 24.82 25.92 .71
EC (1.53) (1.36) (1.73) (1.44) (14.16) (18.98)

ACS = 500 Hz tone burst air-conducted stimuli, IH = reflex hammer, EO = eyes open, EC = eyes closed, p is the p-value from the paired samples t-test between Session 1 and 2, standard deviation is shown in parentheses