Table 1.

Percentage change in the median concentration of particles in various size ranges during the procedures, with respect to the baseline levels (measured in the ten-minute period prior to the start of the procedure). For the final two procedures (repair and the use of 3-in-1 air-water syringe used to remove etch), the values show the percentage change in the single data point recorded during the procedure, relative to the baseline

Procedure Number Duration (mins) Very small (0.08-0.26 μm) Small (0.26-0.9 μm) Medium (0.9-2.6 μm) Large (2.6-10 μm)
Standard debond 1 11:00 104.7 111.7 97.3 136.7
2 11:00 104.4 119.5 82.0 78.7
3 4:00 144.2 246.0 155.1 86.3
Average - 117.8 159.1 111.5 100.6
Debond without air 1 4:10 152.9 344.1 149.4 86.1
2 5:00 171.8 140.4 225.5 367.8
3 4:00 328.3 410.2 3040.3 5195.5
Average - 217.7 298.2 1138.4 1883.1
Debond with water 1 9:00 96.0 133.2 161.1 89.4
2 3:50 100.8 246.7 1523.9 6831.7
Average - 98.4 190.0 842.5 3460.5
Debond with fast handpiece 1 11:00 135.2 84.8 150.0 430.1
2 11:00 96.9 146.7 294.4 179.8
3 11:00 89.1 140.9 401.5 168.2
Average - 107.1 124.1 282.0 259.4
Repair (standard debond) 1 0:30 415.9 328.8 668.5 103.4
3-in-1 air-water syringe 1 0:30 81.2 94.3 157.5 110.7