Skip to main content
. 2020 Nov 5;2020:5193707. doi: 10.1155/2020/5193707

Table 2.

Quantitative evaluation results between ground truth MR images and sMR images: MAE, SSIM, and PSNR.

Model MAE ± SD (HU) SSIM ± SD PSNR ± SD (dB)
U-Net 73.43 ± 9.16 0.946 ± 0.004 32.35 ± 0.78
CycleGAN 88.71 ± 10.04 0.924 ± 0.003 30.79 ± 0.73