Skip to main content
. 2019 Dec 24;12(4):809–822. doi: 10.1007/s12403-019-00339-3

Table 1.

Summary table of adapted sanitary risk inspection checklist for rainwater harvesting systems

Component Sanitary risk items Responses
Roof catchment Risk present (1) Yes; (2) no
Type of risk (1) Birds/bird droppings; (2) plants/leaves; (3) overhanging branches; (4) other (specify)
Guttering channel Dirty gutters (1) Yes;( 2) no; (3) don’t know (cannot see)
Moveable inlet pipe (1) Yes; (2) no; (3) don’t know (cannot see)
Tank inlet Filter box (1) Yes; (2) no; (3) don’t know (cannot see)
Inside tank inlet (1) Fine gravel; (2) coarse stones/gravel; (3) debris/leaves/dirt; (4) sieve; (5) other (specify)
Tank cover Improper cover (1) Yes; (2) no; (3) don’t know (cannot see)
Storage tank Defect (e.g. cracks) in the walls / on the top (1) Yes; (2) no
Depression on the top (1) Yes; (2) no
Tap Tap present (1) Yes; (2) no; (3) don’t know (cannot see)
Tap defective/leaking (1) Yes; (2) no
Concrete floor Concrete floor present (1) Yes; (2) no
Risk present (1) Cracked; (2) broken; (3) dirty
Drainage Inadequate drainage (1) Yes; (2) no
Water fetching method Bucket/container for fetching water (1) Yes; (2) no
Bucket/container left on the ground (1) Yes; (2) no
Dirty bucket/container (1) Yes; (2) no