Table 3. Optimized Reaction Conditions for Complete Microwave-Assisted, Acid-Catalyzed Hydrolysis of Aliphatic PAs Together with Yields, Tm, and Purities of Recovered Monomers and Reinforcement Additivesa.
| MW conditions | recovered
monomer/reinforcement additive | |||||||
|---|---|---|---|---|---|---|---|---|
| entry | sample |  | T (°C) | t (min) | yield (%) | Tm (°C)b | purity (%)c | |
| 1 | PA 66 | 1.25 | 200 | 10 | AA | 90 | 152.6–153.3 | 100.6 ± 0.2 | 
| HMDA | 86 | 100.1 ± 0.3 | ||||||
| 2 | PA 66-GF35 | 1.25 | 200 | 15 | AA | 83 | 152.3–152.9 | 100.7 ± 0.2 | 
| HMDA | 81 | 100.1 ± 0.4 | ||||||
| GF | 97 | |||||||
| 3 | PA 11 | 2.5 | 200 | 10 | 11-AUDAxHCl | 93 | 147.3–148.7 | 100.1 ± 0.2 | 
| 4 | PA 11-GF30 | 2.5 | 200 | 15 | 11-AUDAxHCl | 71 | 147.0–148.6 | 99.8 ± 0.1 | 
| GF | 97 | |||||||
| 5 | PA 11-CF30 | 2.5 | 200 | 20 | 11-AUDAxHCl | 72 | 146.7–147.0 | 99.3 ± 0.2 | 
| CF | 99 | |||||||
| 6 | PA 12 | 2.5 | 200 | 10 | 12-ADDAxHCl | 97 | 160.9–163.5 | 99.9 ± 0.5 | 
| 7 | PA 12-GF50 | 5 | 200 | 15 | 12-ADDAxHCl | 77 | 159.6–162.5 | 97.1 ± 0.3 | 
| GF | 97 | |||||||
| 8 | PA 1010 | 2.5 | 200 | 17 | SA | 89 | 133.1–134.0 | 100.4 ± 0.8 | 
| 1,10-DDA | 78 | 60.4–61.0 | 100.0 ± 0.2 | |||||
Volume of HCl solution was 8 mL in all experiments.
Tm of commercially available monomers: AA: 152.4–153.3 °C; SA: 133.1–134.0 °C; 1,10-DDA: 61.2–62.1 °C; 11-AUDAxHCl: 146.3–149.7 °C; 12-ADDAxHCl: 160.7–163.5 °C.
HPLC purity was determined comparatively to commercial monomers.