Skip to main content
. 2020 Oct 23;8(43):16274–16282. doi: 10.1021/acssuschemeng.0c05706

Table 3. Optimized Reaction Conditions for Complete Microwave-Assisted, Acid-Catalyzed Hydrolysis of Aliphatic PAs Together with Yields, Tm, and Purities of Recovered Monomers and Reinforcement Additivesa.

      MW conditions   recovered monomer/reinforcement additive
entry sample Inline graphic T (°C) t (min)   yield (%) Tm (°C)b purity (%)c
1 PA 66 1.25 200 10 AA 90 152.6–153.3 100.6 ± 0.2
HMDA 86   100.1 ± 0.3
2 PA 66-GF35 1.25 200 15 AA 83 152.3–152.9 100.7 ± 0.2
HMDA 81   100.1 ± 0.4
GF 97    
3 PA 11 2.5 200 10 11-AUDAxHCl 93 147.3–148.7 100.1 ± 0.2
4 PA 11-GF30 2.5 200 15 11-AUDAxHCl 71 147.0–148.6 99.8 ± 0.1
GF 97    
5 PA 11-CF30 2.5 200 20 11-AUDAxHCl 72 146.7–147.0 99.3 ± 0.2
CF 99    
6 PA 12 2.5 200 10 12-ADDAxHCl 97 160.9–163.5 99.9 ± 0.5
7 PA 12-GF50 5 200 15 12-ADDAxHCl 77 159.6–162.5 97.1 ± 0.3
GF 97    
8 PA 1010 2.5 200 17 SA 89 133.1–134.0 100.4 ± 0.8
1,10-DDA 78 60.4–61.0 100.0 ± 0.2
a

Volume of HCl solution was 8 mL in all experiments.

b

Tm of commercially available monomers: AA: 152.4–153.3 °C; SA: 133.1–134.0 °C; 1,10-DDA: 61.2–62.1 °C; 11-AUDAxHCl: 146.3–149.7 °C; 12-ADDAxHCl: 160.7–163.5 °C.

c

HPLC purity was determined comparatively to commercial monomers.