Skip to main content
. 2020 Nov 4;13(21):4965. doi: 10.3390/ma13214965

Table 4.

Impact test results.

Sample No. Types of Combined Materials Impact Strength (J/cm2) Place of Impact the Place of the Crack
1 THA-1 with THA-1 >150 5 mm from the joint It was not broken
2 THA-1 with THA-1 >300 joint It was not broken
3 THA-1 with THA-1 190 joint Next to the point
of impact
4 THA-2 * 33 - At the point
of impact
5 THA-2 * 36 - At the point
of impact
6 THA-1 with THA-2 56 connector At the point
of impact
7 THA-1 with THA-2 76 5 mm from the joint on the THA-2 side At the point
of impact
8 THA-1 with THA-2 150 5 mm from the joint on the THA-1 side At the point
of impact
9 THA-2 with THA-2 15 joint At the point
of impact
10 THA-2 with THA-2 32 5 mm from the joint At the point
of impact

* original material.