Skip to main content
. 2020 Nov 12;20:325. doi: 10.1186/s12903-020-01317-x

Table 1.

Occlusal force loaded on the teeth and stress absorbed by other components of the 3-unit teeth assembly under different occlusal forces

Applied occlusal force (N)
50 100 200 300
Total occlusal force loaded on teeth (N) 44.98 ± 3.58 81.20 ± 5.83 153.34 ± 5.40 185.85 ± 17.01
Percentage (%) of stress absorption from simulated food and tooth-supporting structures 10.04 ± 7.16 18.79 ± 4.32 23.32 ± 5.70 38.04 ± 5.67