Table 6.

Voltage measurements in sinusoidal tests at different frequencies.

Calibrator Settings STCOMET Measurements and Related Errors
Output FFT
f_gen
(Hz)
V_gen
(V)
f1_FFT
(Hz)
E
(mHz)
V1_FFT
(V)
e%
50.0 230 50.0000 0.0 229.26 0.32
42.5 230 42.5025 2.5 229.28 0.31
57.5 230 57.524 24 229.27 0.31