Skip to main content
. 2020 Nov 7;20(21):6361. doi: 10.3390/s20216361

Table 15.

Voltage phase error for II, IV, VI, and XI order harmonics.

Phase Error (deg)
Harmonic Order Min Max Average
II 0.089 0.15 0.12
III 0.028 0.088 0.043
VI 0.065 0.11 0.086
XI 0.089 0.14 0.12