Skip to main content
. 2020 Nov 6;20(21):6327. doi: 10.3390/s20216327

Table 12.

Classification and recognition comparisons.

Paper Device Pods
Sensors
Gestures Train/Test
Users
Class.(%) Recog.(%) HGR
Model
Recognition
Evaluated
Rotation
Performed
Correction of
Rotation
[39] MYO 8 * 5 Gr1 12/12 97.80 - S no no no
[70] Delsys 12 6 Gr3 40/40 79.68 - S no no no
[39] MYO 8 * 5 Gr1 12/12 98.70 - S no no no
[55] Sensors 5 11 Gr4 4/4 81.00 - S no yes no
[57] High Density 96 11 Gr5 1/1 60.00 - S no yes no
[58] MYO 8 * 15 Gr6 1/1 91.47 - S no yes yes
[59] MYO 8 * 6 Gr1 10/10 94.70 - S no yes yes
[63] MYO 8 * 5 Gr2 40/40 92.40 - G no yes yes
S-HGR ** MYO 8 * 5 Gr1 306/306 94.96 94.20 S yes yes yes
G-HGR ** MYO 8 * 5 Gr1 306/306 *** 81.22 80.31 G yes yes yes
S-HGR ** MYO 8* 5 Gr1 306/306 94.96 94.20 S yes yes yes

Myo bracelet used, Specific and General Proposed Models, user-specific (S), and user-general (G) HGR models. Training users are different from testing users; a description of the gestures Gr1 to Gr7 that the analyzed papers study can be found in the Appendix D.