Skip to main content
. 2021 Jan 6;5(1):pkaa090. doi: 10.1093/jncics/pkaa090

Table 2.

Statistically significant laboratory findings at COVID-19 diagnosis compared with reference laboratory values

Biological values of interest Referencea
At COVID-19 diagnosis
Mean of the differences
P b
No. evaluable Median value (IQR) No. evaluable Median value (IQR) No. evaluable Mean value (IQR)
Blood count
 Hemoglobin, g/dL 114 11.6 (10.5-13.2) 100 11.0 (9.2-12.4) 87 1.16 (-2.3 to +0.1) <.001
 Absolute neutrophil count, 109/L 116 3.93 (2.59-5.81) 97 4.19 (2.52-7.32) 85 +0.77 (-1.72 to +1.95) .42
 Absolute lymphocyte count, 109/L 114 1.18 (0.79-1.74) 96 0.83 (0.48-1.38) 82 −0.31 (-0.77 to +0.09) .03
 Platelets, 109/L 114 240 (169-326) 100 190 (132-280) 87 −38.6 (-100 to +26) .02
CRP, mg/L 46 20 (4.6-53.2) 71 84 (41-142) 35 +72 (+11 to +118) .001
a

Reference = laboratory test results obtained no more than 2 months before inclusion in the registry. CRP = C-reactive protein; IQR = interquartile range.

b

Paired 2-sided student test.