Graphene biosensors for the detection of viral and bacterial markers in saliva
Biomarker | Sensing Platform | Detection Method | LODa | Detection Range | Recoveryb | Assay Time | Sample Volume | Preparation | Reference |
---|---|---|---|---|---|---|---|---|---|
H. Pylori | Graphene on Au/Silk | Chemi-resistive | 100 cells | 102 – 106 cells | N/A | 10 min | 1 μL | Whole saliva | (Mannoor et al. 2012) |
HPV-16 L1 | rGO/MoS2/GCE | DPV | 0.1 ng/mL (1.75 pM) | 0.2 – 2 ng/mL (5.3 – 35.3 pM) | 97.1–105.3% | N/A | N/A | Whole saliva | (Chekin et al. 2018a) |
H1N1 | Shellac-derived TrGO/ITO/glass | EIS | 33.11 PFU/mLc 26.04 PFU/mLd |
0 – 10000 PFU/mL | N/A | N/A | N/A | 80% v/v dilution with 1 × PBS | (Joshi et al. 2020) |
Lysozyme | LBA-GR/GCE | EIS | 6 fmol/L | 0.01 – 0.5 pmol/L | N/A | N/A | N/A | Diluted | (Xiao et al. 2013) |
Lysozyme | FAM-aptamers/ssDNA/rGO assembly | Fluorescence | 1.4 μL (21.8 pM)c 6.837 pMd |
1.6 – 14.4 μLc 25 – 175 pMd |
85% | 20 min | 1 mL | 10-fold dilution | (Liu et al. 2017) |
Pyoverdine | AuNPs/Ppy-COOH/GR modified SPE | DPV | 0.33 μM | 1 – 100 μM | 97.8 – 104.93% | N/A | N/A | 1: 10 dilution with PBS | (Cernat et al. 2018) |
Pyoverdine | AuNPs/Ppy-COOH/GR modified SPE | DPV | 333.33 nmol/L | 1 – 100 μmol/L | 102.12% | N/A | N/A | 1:100 dilution with PBS | (Gandouzi et al. 2018) |
S/N = 3, otherwise differently specified
Values obtained in real saliva samples, otherwise differently specified
in saliva
in buffer