Table 2.
Average percentage correct for bimodal and bilateral listeners for each microphone source and speech signal location
CI microphone source | Bimodal listeners | ||
---|---|---|---|
Signal location | |||
HA | Front | CI | |
Processor Mic | 58.6% | 68.3% | 70.1% |
T-Mic 2 | 58.5% | 65.9% | 65.8% |
P-Mic + T-Mic 2 | 62.0% | 63.4% | 68.8% |
Average omnidirectional | 59.7% | 65.9% | 68.2% |
UltraZoom | 59.3% | 77.9% | 38.0% |
StereoZoom | 59.0% | 78.9% | 31.5% |
Bilateral listeners | |||
Signal location | |||
Poorer ear | Front | Better ear | |
Processor Mic | 49.7% | 58.8% | 59.6% |
T-Mic 2 | 47.0% | 59.8% | 61.9% |
P-Mic + T-Mic 2 | 46.6% | 58.8% | 63.7% |
Average omnidirectional | 47.8% | 59.1% | 61.7% |
UltraZoom | 22.4% | 61.7% | 35.3% |
StereoZoom | 24.7% | 68.7% | 30.4% |
Abbreviations: CI, cochlear implant; HA, hearing aid.