Skip to main content
. Author manuscript; available in PMC: 2021 Nov 1.
Published in final edited form as: Hear Res. 2020 Aug 16;397:108053. doi: 10.1016/j.heares.2020.108053

Fig. 7.

Fig. 7.

Panel A: Older listeners’ cortical responses (ONH; black squares) show higher reconstruction accuracies (r values) in quiet and across SNR conditions compared to younger responses (YNH; red circles). Responses of both groups are above the noise floor (blue line). Panel B: ONH responses show a reduction in reconstruction accuracy as the integration time window is narrowed from 500 ms to 150 ms in both quiet and noise conditions, but the YNH responses do not show a similar decrease in reconstruction accuracy. Error bars: ± 1 standard error. *p < 0.05, **p < 0.01, ***p < 0.001, N.S. = not significant. Modified with permission from Presacco et al. (2016a).