Skip to main content
. 2020 Nov 12;5(46):30329–30335. doi: 10.1021/acsomega.0c04964

Table 2. Time Required to Reach the Threshold of 75% Tensile Strength Retention.

temperature (°C) shift factor for a reference temperature at 30 °C shifted time (days) to reach 75% retention
50 7.69 660
60 19.46 537
70 46.63 378
80 106.34 389