Skip to main content
. 2020 Nov 5;9:e62373. doi: 10.7554/eLife.62373

Table 2. Unitary transmission properties by PV+INT subtype.

Table 2—source data 1. PV+INT euIPSC properties.
WT
FS.BC
9 connections
WT
FS.DTC
7 connections
WT
NFS.BC
3 connections
GlobalLis
FS
connections
GlobalLis
IS
connections
euIPSC potency (pA) 171 ± 74 26 ± 5 56 ± 10 71 ± 16 56 ± 20
euIPSC Amplitude (pA) 171 ± 74 24 ± 4 49 ± 15 66 ± 15 48 ± 20
Failure probability 0.01 ± 0.01 0.11 ± 0.05 0.23 ± 0.19 0.03 ± 0.02 0.17 ± 0.06
Latency (ms) 1.2 ± 0.1 1.1 ± 0.1 2.4 ± 0.3 0.9 ± 0.1 1.6 ± 0.1
Decay time constant (ms) 6.6 ± 0.5 7.0 ± 0.8 5.4 ± 0.4 6.5 ± 0.7 7.7 ± 1.1
Postnatal age at time of recording (days) 35 ± 3 30 ± 4 27 ± 1 30 ± 1 27 ± 2