Skip to main content
. 2020 Nov 19;3:100014. doi: 10.1016/j.ibmed.2020.100014

Table 2.

Performance of the AI system in the test dataset.

Diagnosis Sensitivity Specificity AUROC F1 score Brier score MAE
Covid-19 pneumonia (n = 20) 80% 80% 0.84 0.73 0.16 0.28
Non-Covid-19 pneumonia (n = 20) 60% 90% 0.88 0.67 0.14 0.26
Other (n = 20) 65% 83% 0.86 0.65 0.15 0.26

AI: artificial intelligence, AUROC: area under the receiver operating characteristics, MAE: mean absolute error.