Skip to main content
. 2020 Nov 18;10:20032. doi: 10.1038/s41598-020-77014-0

Table 1.

Electrophysiological effects of ranolazine in isolated Langendorff-perfused mouse hearts after IR injury.

APD80 (ms) CaiTD80 (ms) CV (cm/s)
200 ms 100 ms 200 ms 100 ms 200 ms 150 ms 120 ms 100 ms 90 ms 80 ms 70 ms 60 ms
db/db C (N = 11)
Non-IR 82 ± 9* 52 ± 7* 91 ± 7* 69 ± 5* 78 ± 13* 76 ± 13* 74 ± 14* 70 ± 13* 64 ± 12* 57 ± 13* 51 ± 12* 45 ± 12*
IR 86 ± 9* 56 ± 6* 100 ± 9* 77 ± 8* 68 ± 18* 61 ± 16* 57 ± 15* 54 ± 14* 50 ± 12* 47 ± 11* 41 ± 10* 37 ± 10*
db/db R (N = 10)
Non-IR 70 ± 7 48 ± 6 84 ± 11 65 ± 6 88 ± 5 84 ± 8 80 ± 9 75 ± 8 74 ± 11 72 ± 12 64 ± 12 62 ± 10
IR 73 ± 10 51 ± 6 89 ± 9 67 ± 5 82 ± 9 78 ± 8 76 ± 7 70 ± 6 67 ± 7 61 ± 6 58 ± 5 53 ± 6
db/+ C (N = 11)
Non-IR 75 ± 4 46 ± 4* 89 ± 7* 68 ± 3* 83 ± 15 78 ± 13* 75 ± 10* 70 ± 12* 67 ± 13* 60 ± 12* 57 ± 13* 52 ± 11*
IR 78 ± 4 54 ± 4* 96 ± 10* 73 ± 6* 69 ± 12 64 ± 13* 59 ± 11* 55 ± 9* 51 ± 9* 46 ± 8* 43 ± 7* 38 ± 7*
db/+ R (N = 10)
Non-IR 71 ± 10 46 ± 2 84 ± 6 65 ± 4 90 ± 25 89 ± 25 85 ± 27 83 ± 28 80 ± 25 75 ± 23 67 ± 19 61 ± 17
IR 73 ± 14 49 ± 5 86 ± 10 66 ± 5 86 ± 22 82 ± 21 80 ± 22 75 ± 24 72 ± 21 68 ± 22 64 ± 21 56 ± 16

Values are mean ± SD. APD80, action potential duration at 80% repolarization; CaiTD80, effective refractory period; CV, conduction velocity; IR, ischemia–reperfusion. * indicates P < 0.05 for non-IR vs. IR.