Table 2. Carbon Removal Kinetic Parameters of All Samples (n = 1).
T (°C) | sample | regression equation | correlation coefficient R2 | activation energy E (kJ/mol) | pre-exponential factor A (min–1) | 2RT/E |
---|---|---|---|---|---|---|
480–680 | Ni-Ca-1 | y = −5212.37x – 4.04 | 0.9917 | 43.34 | 917.25 | 0.1842 |
Ni-Ca-2 | y = −3997.94x – 5.93 | 0.9936 | 33.24 | 106.29 | 0.2401 | |
Ni-Ca-4 | y = −3273.84x – 7.17 | 0.9933 | 27.22 | 25.19 | 0.2932 | |
Ni-Ca-6 | y = −2776.21x – 7.79 | 0.9771 | 23.08 | 11.49 | 0.3457 |