Skip to main content
. 2020 Oct 5;131(5):E1415–E1421. doi: 10.1002/lary.29122

Fig. 2.

Fig. 2

Difference in mean particle concentrations between diagnostic nasal endoscopy and nasal endoscopy with debridement. Zero reference normalized to combined preprocedure data in the cohort. Endoscope use during diagnostic endoscopy was associated with a nonsignificant mean particle difference of 173 p/ft3 (95% CI −1,139 to 793; P = .698) compared to preprocedure levels. Endoscope use prior to tissue manipulation in nasal endoscopy with debridement was associated with a trending mean increase of 1,629 p/ft3 (95% CI −96 to 3,354; P = .063).