Skip to main content
. 2020 Oct 5;131(5):E1415–E1421. doi: 10.1002/lary.29122

TABLE III.

Mean Particle Concentration (percentage) and Particle Size Measured in Particles/Foot3 at Distinct Timepoints Throughout Diagnostic Nasal Endoscopy and Nasal Endoscopy with Debridement.

Particle Size (um) Total 0.3 0.5 1 2.5 5 10
Mean particle concentration (Percent)
Empty room 3,863.7 2,938 (76.0) 810 (21.0) 102 (2.6) 12 (0.3) 1 (0.03) 0.7 (0.01)
Diagnostic nasal endoscopy
Pre 6,195 4,509 (72.8) 1,388 (22.4) 250 (4.0) 36 (0.58) 7 (0.10) 5 (0.07)
During 6,022 4,444 (73.8) 1,307 (21.7) 231 (3.8) 32 (0.53) 5 (0.08) 3 (0.05)
Post 6,014 4,393 (73.0) 1,335 (22.2) 245 (4.1) 31 (0.52) 6 (0.09) 4 (0.07)
Nasal endoscopy with debridement
Pre 5,539 4,014 (72.5) 1,252 (22.6) 228 (4.1) 35 (0.64) 6 (0.12) 4 (0.08)
Scope 7,169 5,224 (72.9) 1,603 (22.4) 288 (4.0) 43 (0.60) 7 (0.10) 4 (0.06)
Cold instrumentation 8,002 5,819 (72.7) 1,799 (22.5) 335 (4.2) 41 (0.51) 5 (0.06) 3 (0.04)
Suction 8,514 6,160 (72.4) 1,951 (22.9) 341 (4.0) 50 (0.59) 8 (0.09) 4 (0.05)
Post 5,816 4,232 (72.8) 1,300 (22.3) 234 (4.0) 41 (0.70) 6 (0.10) 3 (0.05)