Table 2.
Association and Dissociation Rate Constants Calculated from ABF Simulations for AMT+ or RMT+ in WT or M2 S31N
ABF Rate Constant Results | ||||
---|---|---|---|---|
k1 (M−1 s−1) = kc × e−ΔG/kT | k2 (s−1) | EP k1 (M−1 s−1) | EP k2 (s−1) | |
WT M2(+1) AMT+ | 380.9 | 1.11 × 10−4 | 372 | 2.3 × 10−4 |
WT M2(+1) RMT+ | 617.6 | 1.27 × 10−4 | 659 | 1.58 × 10−4 |
S31N M2(+1) RMT+ | 1.61 × 105 | 24.9 | 3622 | 2.73 |
Electrophysiologically measured rate constants (EP) are included for reference.