Skip to main content
. Author manuscript; available in PMC: 2021 Dec 1.
Published in final edited form as: J Pharm Sci. 2020 Sep 8;109(12):3598–3607. doi: 10.1016/j.xphs.2020.09.007

Table 2.

Summary of PLS regression results for encoded independent variables

Variable Drug release (%)
120 min in pH 1.2
30 min in pH 6.8
45 min in pH 6.8
Coeff. P Coeff. P Coeff. P
Constant 6.75 0.000 83.04 0.000 93.05 0.000
Drug load 0.72 0.024 3.50 0.013 1.73 0.009
SA content −2.35 0.000 −2.10 0.064 −0.22 0.579
Pellet size −2.65 0.000 −6.97 0.001 −4.77 0.000
(Drug load)*(SA content) 0.12 0.529 −0.97 0.259 −1.10 0.027
(Drug load)*(Pellet size) −0.32 0.154 0.82 0.327 0.00 0.995
(SA content)* (Pellet size) −0.19 0.356 1.17 0.189 −0.25 0.473
Goodness of prediction (Q2) 0.672 0.511 0.737
Goodness of fit (R2) 0.988 0.962 0.982
P-Model Correctness 0.001 0.008 0.002