Skip to main content
. 2020 Nov 21;26(43):6867–6879. doi: 10.3748/wjg.v26.i43.6867

Table 2.

Hypoxemia and lowest pulse oxygen saturation during the gastroscopy, and interventions related to hypoxemia and adverse events


WNJT group (n = 144)
Nasal cannula group (n = 144)
P value
Total occurrence of hypoxemia 3 (2.1) 21 (14.6) 0.000
Hypoxemia 2 (1.4) 19 (13.2) 0.000
Severe hypoxemia 1 (0.7) 2 (1.4) 1.000
Lowest SpO2 98 (97, 99) 96 (93, 98) 0.000
Airway opening maneuvers 4 (2.8) 36 (25) 0.000
Facemask ventilation 0 (0) 4 (2.8) 0.131
Body movement 8 (5.6) 9 (6.3) 0.803
Cough 10 (6.9) 11 (7.6) 0.821
Epistaxis (0/1/2/3) 0/7/0/0 (4.9) 0 (0) 0.022
Sore throat 2 (1.4) 3 (2.1) 1.000

Data are presented as median (interquartile range) or number of patients (percent). SpO2: Pulse oxygen saturation; WNJT: Wei nasal jet tube.