Summary of current measurement results of radon concentration and annual effective dose of indoor radon in dwelling buildings for the mean values of floor levels (B1, GF, F1, F2, F3, F4) and for the basement level (B1) compared with the literature-reported values of lower range and higher ranges for various Jordanian cities.

City Literature-reported lower values Bq/m3 Literature-reported higher values Bq/m3 Current measurement (B1, GF, F1, F2, F3, F4) Bq/m3 Current measurement (B1) Bq/m3 Current measurement of effective dose (B1, GF, F1, F2, F3, F4) mSv/year Current measurement of effective dose (B1) mSv/year
Zarqa 6.9 113.1 49.9 143.9 1.3 3.6
Madaba 28 212 54.1 122.8 1.4 3.1
Amman 20 440 30.8 48.3 0.8 1.2
Aqaba 12 64 47.6 71.3 1.2 1.8
Karak 24 556 64.9 107.0 1.6 2.7
Ma'an 40 440 87.1 216.3 2.2 5.5
Mafraq 12 80 34.0 52.2 0.9 1.3
Irbid 3.1 163.9 72.3 142.2 1.8 3.6
Russeifa 4 1532.9 102.9 314.7 2.6 7.9
Grand meana 16.7 ± 12.4 400.2 ± 460.9 60.4 ± 56.2 135.4 ± 85.4 1.5 ± 0.6 3.4 ± 2.2

aGrand arithmetic mean and its one sigma standard deviation for each Jordanian province.