Table 3.
Parts | Temp. (°C) |
Duration (hours) |
Rationale |
---|---|---|---|
Passive samples (#1.1 to #1.5) |
116 | 48 | Curing of glue, removing adhesive volatiles |
Geological samples (#2.1 to #5.6) |
120 | 120 | Cleaning procedure after characterization |
PET sample (#1.6) |
120 | 72 | Removing volatiles |
Remove Before Flight (RBF): assembly and handling fixture | 110 | 48 | Final steps of cleaning procedure |
SCCT (whole system) | 115 | 120 | Subsystem level DHMR, prior to delivery |